Thanks a lot for the fast answer!
I used both:
Loading PBPX in PB, changed the Setting “EXE Format” in “EXE Output Configuration”, save, Exit, and reload PBPX file.Then EXE Format was again 32.bit.
In my deployment Tools I use PB command line, and PBD file with “EXEType=1”. Running the...
In a Paquet Builder Project I Change the EXE Format from Default 32-bit to 64-bit. After saving the pbpx, Close app and reload pbpx file, the setting is again on 32-bit.
OP System is Windows 10 Pro x64.
Wehen Building the selfextracting file, I use Setting ExeType=1, but it seems not to work as...
Hi, I did test the debug build you have sent me successfully 😊
I will observe the behaviour for a couple of days and will give you a feedback, in case I find a problem.
Thanks a lot for your help!
Albert
For PaquetBuilder GUI there is a switch “Do not show automatic update notification messages” in General Options.
If “Live Update” is switched on, I cannot use the command line compiler in a automation, because PaquetBuilder hangs in this dialog.
How can I disable these messages for the command...
I got it to work, but do not understand it completely:
The commandline compiler exe has 2 parameters, first is the directive file, and second the log file, both including the directory path.
My PDB directory path has no spaces, so I did not use quotation marks according the manual. The log file...
I have a package template with 32bit EXE format, which is building fine. As soon as I use a batch file and a directive file, the commandline compiler crashes at startup (… stopped working).
My directives look like this (same settings as in PBPX file):
[General]...
Thanks a lot for this really fast reaction 😄
I enhanced my project with some custom actions now and find this really easy to use and functional. My compliment for this software!
Reproduce:
Use a directive file with a template and linked folder as source.
If in the source directory are located files like this:
FILENAME
FILENAME.EXT
both files are not included in the selfextracting executable.
The same project/directive combination works with version 3.2.
Regards,
Albert
yes, I have a project template and all files in the template have the target variable. The complete directives are like this;
[General]
ProjectTemplate=D:\ecscad\main\source\MMTInstaller\Package\ecscad2015HotfixTemplateAddon.pbpx
Title=ecscad 2015 AddonX64 - Hotfix 1
Company=Mensch und Maschine...
Hi,
I have a project which is extracting files of components to a custom folder defined with a user path variable.
This is working fine with building from the project directly. As soon I am using a directive file, PaquetBuilder extracts not to the custom, but default directory.
The directives...